Breast Imaging Frequently Asked Questions Update 2019

The following Q&As address Medicare guidelines on the reporting of breast imaging procedures. Private payer guidelines may vary from Medicare guidelines and from payer to payer; therefore, please be sure to check with your private payers on their specific breast imaging guidelines.

What differentiates a diagnostic from a screening mammography procedure?

Medicare’s definitions of screening and diagnostic mammography, as noted in the Centers for Medicare and Medicaid’s (CMS’) National Coverage Determination database, and the 黑料网’s (黑料网’s) definitions, as stated in the 黑料网 Practice Parameter of Screening and Diagnostic Mammography, are provided as a means of differentiating diagnostic from screening mammography procedures. Although Medicare’s definitions are consistent with those from the 黑料网, the 黑料网's definitions of screening and diagnostic mammography offer additional insight into what may be included in these procedures. Please go to the CMS and 黑料网 Web site links noted below for detailed comments about these studies.

Medicare Definitions (CMS National Coverage Determination for Mammograms 220.4)

Per the , the following definitions for screening and diagnostic mammography are provided:

“A diagnostic mammogram is a radiologic procedure furnished to a man or woman with signs and symptoms of breast disease, or a personal history of breast cancer, or a personal history of biopsy - proven benign breast disease, and includes a physician's interpretation of the results of the procedure.”

“A screening mammogram is a radiologic procedure furnished to a woman without signs or symptoms of breast disease, for the purpose of early detection of breast cancer, and includes a physician’s interpretation of the results of the procedure. A screening mammogram has limitations as it must be, at a minimum a two-view exposure (cranio-caudal and a medial lateral oblique view) of each breast.”

Medicare will not pay for a screening mammogram performed on a woman under the age of 35. Medicare will pay for only one screening mammography procedure performed on a woman over age 34 but under age 40. For an asymptomatic woman over age 39, payment may be made for a screening mammography performed after at least 11 months have passed following the month in which the last screening mammography was performed.

As noted in the “the term ‘screening mammography’ means a radiologic procedure provided to an asymptomatic woman for the purpose of early detection of breast cancer…” Therefore, Medicare does not cover screening mammography for a man.*

Medicare will pay for a diagnostic mammogram when one of the following conditions is met:

  • A patient has distinct signs and symptoms for which a mammogram is indicated

  • A patient has a history of breast cancer

  • A patient is asymptomatic but, on the basis of the patient’s history and other factors the physician considers significant, the physician's judgment is that a [diagnostic] mammogram is appropriate

*Information on the use of modifier KX on claims for transgender patients

黑料网 Definitions (as defined in the 黑料网 Practice Parameter of Screening and Diagnostic Mammography)

Screening mammography is a radiological examination to detect unsuspected breast cancer in asymptomatic women. Standard views are obtained, and thus the interpreting physician does not need to be present at the facility to monitor the examination when the patient is imaged.

The examination should ordinarily be limited to craniocaudal (CC) and mediolateral oblique (MLO) views of each breast. On occasion, supplementary views may be required to visualize breast tissue completely or optimally, but such views are not ordinarily part of the routine screening examination except for women with implants. Views may be modified to accommodate patient positioning limitations.

Diagnostic mammography is a radiologic examination performed to evaluate patients who have signs and/or symptoms of breast disease, imaging findings of concern, or prior imaging findings requiring specific follow-up. Diagnostic mammography requires direct supervision.1 A diagnostic mammogram may include MLO, CC, and/or additional views to evaluate an area of clinical or radiographic concern. Additional mammographic views might include spot compression, spot compression with magnification, tangential views, or other special views. When selecting a view, the proximity of the area of concern to the image receptor should be considered.

The written or electronic request for a diagnostic mammography examination should provide sufficient information to demonstrate the medical necessity for the examination and allow for its proper performance and interpretation.

As noted in Section II. Indications, B. Diagnostic Mammography, of the 黑料网 Practice Parameter of Screening and Diagnostic Mammography, indications for diagnostic mammography include:

  1. To assess certain clinical findings that may include a palpable abnormality, persistent focal area of pain or tenderness, bloody or clear nipple discharge, or skin changes.
  2. A finding detected on screening mammography that requires further imaging evaluation. This could either be a call-back examination following an abnormal screening mammogram, or conversion of a screening mammogram to a diagnostic mammogram when an abnormality is detected at the time of the screening visit.
  3. Short-interval follow-up for probably benign radiographic findings as defined by the 黑料网 Breast Imaging Reporting and Data System (BI-RADS®).
  4. Asymptomatic patients previously treated for breast cancer may undergo screening or diagnostic mammography at the discretion of the facility.
  5. Determination that a patient scheduled for screening mammography has a clinical problem, as noted above in section II.B.1. The facility should have a process whereby screening mammography can be converted to diagnostic mammography.
    mammography can be converted to diagnostic mammography.

When billing for a Medicare patient who has had a mammogram, one must be cautious to follow the Centers for Medicare and Medicaid Services’ definition. One should consult the local Medicare carrier or Medicare Administrative Contractor to determine how to code for some scenarios. Note that non-Medicare third-party payers should be contacted as they may handle coverage of screening and diagnostic mammograms differently.

1Direct supervision is defined as the physician being present and immediately available to furnish assistance and direction throughout the performance of the procedure. Direct supervision may also be accomplished via telemammography as long as the interpreting physician is immediately available.

How are additional views reported when performed during a screening mammography procedure to better visualize breast tissue?

Additional views performed to better visualize breast tissue are considered part of the base procedure performed and not reported separately. Although a screening examination should ordinarily be limited to craniocaudal (CC) and mediolateral oblique (MLO) views of each breast, on occasion, supplemental views may be required to visualize breast tissue completely or optimally, but such views are not ordinarily part of the routine screening examination except for women with implants.2 When pathology is suspected, a recommendation for additional imaging studies, diagnostic mammography, or biopsy may be warranted.

2黑料网 Practice Parameter for the Performance of Screening and Diagnostic Mammography

How is computer-aided detection (CAD) coded when performed in addition to mammography?

As of January 1, 2017, three Category I codes were created to describe mammography (both digi¬tal and analog) with computer-aided detection (CAD) when performed. These bundled codes (77065, 77066, 77067) replaced CPT CAD codes 77051 and 77052, and mammography codes 77055, 77056, 77057. For dates of service on or after January 1, 2018, the Centers for Medicare & Medicaid Services (CMS) has operationalized these CPT codes, and deleted the HCPCS Level II G codes G0202, G0204, and G0206 that used to mirror the CPT codes 77065, 77066, 77067.

It is recommended that providers check with their third party payers for their specific payer requirements.

What code(s) should be reported to describe a screening mammogram when additional magnification views are required for a suspected abnormality? May I code both a diagnostic mammogram and a screening mammogram and is an order required?

If a screening mammogram is performed and, after review of the images, pathology is suspected, the interpreting physician is allowed to order additional images. When additional views are obtained, Medicare states that it is appropriate to charge for both a screening mammogram and a diagnostic mammogram whether the studies are performed on the same or different days. If the additional views are done on the same day as the screening mammogram, the diagnostic study should be reported with the GG modifier, which Medicare uses for tracking purposes. This modifier designates the performance and payment of a screening mammogram and diagnostic mammogram on the same patient, same day.

In March 2015, CMS responded to an appeal from the 黑料网 regarding a newly implemented National Correct Coding Initiative (NCCI) edit for screening mammography and diagnostic mammography performed on the same patient on the same date of service. CMS elected to retain these NCCI edits. Per CMS, if a provider performs both screening and diagnostic mammography on the same patient on the same date of service, CMS instructions require that a provider report modifier GG with the diagnostic mammography code (77065 or 77066,). However, because modifier GG is not an NCCI-associated modifier and will not bypass the NCCI edit, providers are instructed to additionally append modifier 59 (Distinct Procedural Service) to the screening mammography (77067) to bypass the NCCI edits.

When a patient has a screening mammogram performed on one day and returns on another day for the additional diagnostic mammogram, both the screening mammogram and diagnostic mammogram services should be coded separately. In this scenario, no GG modifier would be required.

See Medicare Claims Processing Manual, Chapter 18, Preventive and Screening Services, Section for additional information on the reporting of a screening and diagnostic mammogram performed on the same day.

Is it appropriate to combine the interpretation of a screening and a diagnostic study into one report or must two separate reports be issued?

Yes, it is appropriate to combine the interpretation of a screening and a diagnostic study into one report. According to the 黑料网 Breast Imaging Reporting and Data System (BIRADS®)* frequently asked questions (see Multiple Procedures section):

The facility has the option of issuing either separate reports or one combined report. If two reports are issued, each must contain its own overall final assessment (21 CFR 900.12(c)(1)(iv)). In either case, the facility can report the exam(s) on the same piece of paper.

If the facility decides to issue a single combined report, the facility needs to be aware of the following:

  1. A combined report must contain a single overall final assessment for the two exams (21 CFR 900.12(c)(1)(iv)).
  2. The combined report should make it clear that it is combining the results of the screening and diagnostic studies. This is especially important if questions arise about whether the exams were billed correctly.
  3. Issuing a single combined report with a single final assessment may skew the facility’s medical audit results.
  4. Though some computerized reporting systems may consider this a single exam (rather than two), the FDA [Food & Drug Administration] would still allow facilities to count both exams toward meeting the continuing experience requirement.

*BI-RADS® was developed by the 黑料网 to standardize mammographic reporting, improve communication, reduce confusion regarding mammographic findings, aid research, and facilitate outcomes monitoring.

How do you code for a unilateral screening mammogram in a patient who has had one of her breasts removed? The code descriptor for a screening mammogram specifies that it is a bilateral study.

When a screening mammography study is ordered and performed on a patient who has only one breast, it is appropriate to report 77067 (Screening mammography, bilateral (2-view study of each breast), including computer-aided detection (CAD) when performed. Because the CPT code descriptor for 77067 states “bilateral,” it would be appropriate to use a 52 modifier (reduced level of service) to designate a screening procedure of only one breast. However, radiology practices should check with their local carrier and other third-party payers regarding the use of the 52 modifier in this situation, because some payers have stated that a 52 modifier is not necessary for reporting a unilateral screening mammogram.

We received an order for a screening mammogram on one breast and a diagnostic mammogram on the other breast. Is it appropriate to report a unilateral screening and a unilateral diagnostic mammogram for this service?

No, it is not appropriate to perform a screening exam on one breast and a diagnostic exam on the other breast. Whenever a diagnostic study is indicated, it is appropriate to do a diagnostic mammogram on one or both breasts as indicated. If a patient presents with a clinical abnormality of the breast, a diagnostic study should be performed. However, it is recommended that radiology practices check with their local carriers and third-party payers as they may have different guidelines.

What is the correct way to code for a mammography examination on a mastectomy patient when one or two additional images are taken of the axillary region on the mastectomy side? Is it correct to report a bilateral mammography code even though there is no breast tissue? Would this be considered a screening or diagnostic study?

Yes, it is correct to code a bilateral mammography examination code even though there is no obvious breast tissue because both the side of the remaining breast and the mastectomy side are being imaged. This is analogous to a mammogram of a man, where there is little breast tissue. Depending on the type of mastectomy performed, there may be residual breast tissue left behind, usually in the axillary tail. If there is enough clinical concern to warrant imaging, there is probably clinical concern that a small amount of breast tissue remains. This should, therefore, be billed as a bilateral diagnostic mammogram (77066).

Should a screening mammogram or a diagnostic mammogram be performed on an asymptomatic patient with augmented breasts (e.g., breast implants)?

According to the 黑料网 Practice Parameter for Performance of Screening and Diagnostic Mammography, the facility and/or interpreting physician can determine whether a woman with augmented breasts (breast implants) is imaged as a screening or a diagnostic patient. The practice parameter notes the following screening mammography indications for a woman with breast augmentation:

6. Woman with breast augmentation
a. Asymptomatic women with breast implants may undergo screening mammography.
b. Facilities must have procedures in place to inquire whether patients have breast implants before a mammogram is performed.
c. If a facility does not provide implant imaging services, it should refer the patient to other facilities that provide such services.

However, the Centers for Medicare and Medicaid Services’ (CMS) payment policy for a diagnostic mammogram does not recognize asymptomatic patients with augmented breasts as diagnostic. Medicare will pay only for a screening mammogram for an asymptomatic woman with breast implants.

Because Medicare denies the necessity of a diagnostic mammogram for an asymptomatic patient with augmented breasts, it is recommended that the physician have the patient sign an form so that the radiologist may bill the patient for the procedure. If the patient and referring physician decide that a screening mammogram should be performed, then the patient would receive a screening mammogram.

The 黑料网 practice parameters are an educational tool designed to assist practitioners in providing appropriate radiologic care for patients. They are not inflexible rules or requirements of practice and are not intended, nor should they be used, to establish a legal standard of care. The ultimate judgment regarding the propriety of any specific procedure or course of action must be made by the physician or medical physicist in light of all the circumstances presented. Thus, an approach that differs from the guidelines, standing alone, does not necessarily imply that the approach was below the standard of care.3

3黑料网 Practice Parameter for the Performance of Screening and Diagnostic Mammography, Res. 35 - 2018)*.

What type of mammogram should a patient receive who has a personal history of biopsy-proven benign breast disease?

As noted in the Dec. 8, 1995 Federal Register, the Centers for Medicare and Medicaid Services expanded its definition of diagnostic mammography to include a personal history of biopsy-proven benign breast disease, thereby allowing the attending physician and the patient the opportunity to determine whether a screening mammogram or a diagnostic mammogram is performed.

Is there a guideline that states that patients with a history of mastectomy must revert back to a screening mammography study after a set number of negative diagnostic studies or after a specified number of years post mastectomy?

No, Medicare does not have a specific requirement that a patient with a history of mastectomy must revert back to a screening mammography study after a set number of negative diagnostic studies or after a specified number of years post mastectomy. CMS allows the attending physician and the patient the flexibility to choose whether they want to continue with a diagnostic mammogram or revert back to the screening process.

In a freestanding office or independent diagnostic testing facility (IDTF) setting, is a separate order required for a breast ultrasound study recommended by a radiologist to further evaluate a suspicious finding on screening mammography?

Yes, in freestanding office and IDTF settings a separate order is required for the addition of a breast ultrasound study following a screening mammography procedure to further evaluate a suspicious finding. The rationale that allows for the performance of a diagnostic mammogram following a screening mammogram without an order from the referring physician does not apply to additional diagnostic testing such as ultrasound or MRI (see Terrence Kay letter to 黑料网).

The national office of the Health Care Financing Administration (HCFA) notified the 黑料网 that Medicare proposed and adopted the diagnostic mammography exception to the Ordering of Diagnostic Tests Rule (see ) because Congress made the Food and Drug Administration, rather than HCFA, responsible for the conditions under which mammograms are covered. In addition, the screening mammography benefit contains no requirement for a physician’s order. Thus, a beneficiary could receive the screening mammogram on a walk-in basis, with no treating physician to order the subsequent diagnostic procedure. Note that the Ordering of Diagnostic Test Rule does not apply in the hospital setting (see Thomas Scully letter to American Hospital Association, Response #1).

For more information on the Ordering of Diagnostic Test Rule, reference Further Clarification on the Ordering of Diagnostic Tests Rule in the July- Aug 2003 黑料网 Radiology Coding Source

How should the use of computer-aided detection software be reported in conjunction with breast sonography services?

No code is available to describe computer-aided detection (CAD) performed in conjunction with breast ultrasound. CAD performed in conjunction with breast sonography is reported with the unlisted CPT code 76999 (Unlisted ultrasound procedure (e.g., diagnostic, interventional)) to describe the CAD analysis and CPT code 76641 (Ultrasound, breast, unilateral, real time with image documentation, including axilla when performed; complete) or 76642 (Ultrasound, breast, unilateral, real time with image documentation, including axilla when performed; limited) to describe the breast ultrasound study.

How should breast MRI with the use of computer-aided detection software be reported?

Prior to January 1, 2019, breast MRI with CAD was reported with Codes 77058, 77059, and 0159T, these codes have been deleted and replaced with new codes 77046-77049. The 黑料网 presented a code proposal at the June 2017 CPT Editorial Panel meeting that requested the MRI breast codes bundle in the performance of CAD, when performed. The new CPT codes were approved for use beginning January 1, 2019.

Table 1

CPT Description CPT Codes
MRI, breast, without contrast; unilateral 77046
MRI, breast, without contrast; bilateral 77047
MRI, breast, without and with contrast, including CAD, when performed; unilateral 77048
MRI, breast, without and with contrast, including CAD, when performed; bilateral 77049

Is an order required for the use of computer-aided detection (CAD) with breast imaging procedures, such as mammography, magnetic resonance imaging (MRI) and ultrasound? Must the use of CAD be dictated in the report?

No, an order is not required for the use of CAD performed in conjunction with breast imaging procedures, such as mammography, MRI, and ultrasound. When CAD is performed, a statement such as “CAD software was used” should be inserted into the report.1

 As noted in the Winter 2007 issue of the AMA/黑料网 Clinical Examples in Radiology, an order is not required for the performance of CAD because CAD is covered under the .

The Centers for Medicare and Medicaid Services informed the 黑料网 that the Ordering of Diagnostic Tests Rule allows for performance of CAD in conjunction with mammography without a written order from the referring (treating) physician. Because there is no medical necessity prerequisite for the use of CAD with mammography procedures, and if all aspects of CAD are performed in conjunction with mammography, the radiologist may determine whether or not CAD should be performed. The use of CAD is covered under the Radiologist Exception as noted in Medicare Transmittal #1725:

15021 (E)(1) Test Design [see .]

Test Design 

Unless specified in the order, the interpreting physician may determine, without notifying the treating physician/practitioner, the parameters of the diagnostic test (e.g., number of radiographic views obtained, thickness of tomographic sections acquired, use or non-use of contrast media).

1AMA/黑料网 Clinical Examples in Radiology Volume 1, Issue 4; Fall 2005, p. 13.

For more information on the Ordering of Diagnostic Test Rule, reference Further Clarification on the Ordering of Diagnostic Tests Rule in the July- Aug 2003 黑料网 Radiology Coding Source 黑料网 Radiology Coding Source July-August 2003

Is it appropriate to separately code for the review of prior mammographic images when those images are not available for comparison at the time of the current mammogram interpretation?

No, it is not appropriate to separately code for the review of prior mammographic images when they are not available for comparison at the time of interpretation of the current images. The comparison of prior images, which may be an important part of diagnostic mammography, is considered part of the mammography procedure. Radiology practices should work to ensure images are available for comparison at the time of the current mammography interpretation.

When digital subtraction is used in conjunction with a breast magnetic resonance imaging (MRI) with contrast study, is it appropriate to report the digital subtraction?

Digital subtraction should not be reported in addition to the code for a breast MRI with contrast study or any other MRI study. Digital subtraction is a scanner-performed function that generates another set of images. This is similar to another pulse sequence in MRI or another set of windows in computed tomography. Therefore, the digital subtraction would be inherent in the breast MRI procedure. It is not a post-processing function on a separate workstation.

Is a written order required for breast tomosynthesis?

An order for breast tomosynthesis, as described by the breast tomosynthesis codes (77061, 77062, 77063, G0279), is not required and would fall within the Ordering of Diagnostic Tests Rule exception. However, when breast tomosynthesis is used, the breast tomosynthesis procedure should be documented in the report. See the for the latest guidelines on the Ordering of Diagnostic Tests Rule.

For more information on the Ordering of Diagnostic Test Rule, reference Further Clarification on the Ordering of Diagnostic Tests Rule in the July- Aug 2003 黑料网 Radiology Coding Source

Is it appropriate to report the 3-D rendering code 76376 when the referring physician did not include 3-D in the order?

In the past, the 黑料网 maintained that an order for 2D and 3D reconstruction imaging was not necessary because this was covered under the Ordering of Diagnostic Tests Rule test design exception (). However, based on the exponential rise in the use of 3D rendering codes 76376 (not requiring image post-processing on an independent workstation) and 76377 (requiring image post-processing on an independent workstation) and in the number of practice investigations evolving out of overutilization (routine use), the 黑料网 strongly encourages radiology practices to obtain an order from the referring physician in the non-hospital setting. In the hospital setting, radiologists may generate their own order, but they are strongly encouraged to justify medical necessity for the use of 3D rendering in a separate dictation.

For more information on the Ordering of Diagnostic Test Rule, reference Further Clarification on the Ordering of Diagnostic Tests Rule in the July- Aug 2003 黑料网 Radiology Coding Source

How do I code for breast marker placement in the absence of performing a biopsy?

Codes 19281-19288 were specifically created to describe breast marker placement in the absence of performing a biopsy. To report bilateral image-guided placement of localization devices see codes 19281, 19283, 19285, or 19287 for the initial lesion localized, depending on the modality used for imaging guidance. The contra-lateral and each additional breast image-guided localization device placement(s) is reported with codes 19282, 19284, 19286, and 19288. For example, when a breast localization device is placed using stereotactic guid¬ance, code 19283 is reported for the first lesion and add-on code 19284 for each additional lesion. If the patient subsequently goes on to surgical excision the same day, it is appropriate to report the radiograph of the surgical specimen using code 76098, Radiological examination, surgical specimen.

When I do breast biopsies or localize breast lesions using metallic pellets, radioactive seeds, Radio-frequency identification (RFID) devices or other localization devices instead of traditional clips or localization wires, how are these markers reported?

Metallic pellets, radioactive seeds, RFID devices or any other localization devices used during breast biopsy or breast localization are all included in codes 19081-19086 and 19281-19288. Note that these codes are used once per lesion localized, regardless of the number of localization devices placed in or around the lesion (i.e., if mammographically-guided needle localization is performed using two radioactive seeds to designate the margins prior to surgical excision, code 19281 is still only reported one time).

Is it appropriate to separately report a specimen radiograph performed after a breast localization procedure?

Yes, it is appropriate to report radiographs of a surgical specimen (76098) performed after breast localization (19281-19288). However, radiographs of the specimen samples obtained at the time of biopsies are included in the breast biopsy codes (19081-19086).

What CPT code(s) should be used to report a percutaneous breast biopsy?

Percutaneous breast biopsy procedures are reported with CPT codes 19081-19086 and 19100 based on whether the procedure performed is with or without imaging guidance. When percutaneous placement of a localization device is performed without the performance a breast biopsy, see codes 19281-19288.

Table 1 below provides a summary of the breast biopsy and placement of breast localization device codes. For detailed guidelines on the reporting of these codes, please reference the AMA’s CPT 2019 introductory notes, which state the following:

  • When more than one biopsy or localization device placement is performed using the same imaging modality, use an add-on code whether the additional service(s) is on the same or contra-lateral breast.
  • If additional biopsies or localization device placements are performed using different imaging modalities, report another primary code for each additional biopsy or localization device placement performed using a different image guidance modality.
  • When more than one breast biopsy is performed using the same imaging modality, use an add-on code whether the additional service(s) is on the same or contra-lateral breast.
  • If additional biopsies are performed using different imaging modalities, report another primary code for each additional modality.
  • To report bilateral image-guided breast biopsies, report 19081, 19083, or 19085 for the initial biopsy.
  • The contra-lateral and each additional breast image guided biopsy are then reported with code 19082, 19084 or 19086
  • The biopsy procedure code is submitted per lesion and NOT per sample.

Table 1: Reporting of Breast Biopsy and Placement of Location Devices

BREAST NEEDLE BIOPSY CPT
Breast biopsy w/o imaging guidance, percutaneous 19100
Stereotactic guidance, 1st lesion 19081
Stereotactic guidance, each additional lesion  19082
Ultrasound guidance, 1st lesion  19083
Ultrasound guidance, each additional lesion  19084
Magnetic resonance guidance, 1st lesion  19085
Magnetic resonance guidance, each additional lesion 19086
Tomosynthesis guidance w/o stereotactic 19499

Breast biopsy includes: imaging, placement of localization device(s), and imaging of biopsy specimen, when performed

BREAST LOCALIZATION DEVICE(S) W/O BREAST BIOPSY CPT
Mammographic guidance, 1st lesion 
19281
Mammographic guidance, each additional lesion  19282
Stereotactic guidance, 1st lesion  19283
Stereotactic guidance, each additional lesion  19284
Ultrasound guidance, 1st lesion  19285
Ultrasound guidance, each additional lesion  19286 
Magnetic resonance guidance, 1st lesion  19287
Magnetic resonance guidance, each additional lesion  19288
Surgical specimen radiography  76098

What CPT code(s) should be used to report Fine Needle Aspiration (FNA) biopsy(ies) of the breast(s) in 2019?

Effective for dates of service on or after January 1, 2019, CPT codes 10004-10012, and 10021 are used to describe fine needle aspiration biopsies of the breast. CPT code 10022 has been deleted and is no longer available for use.

The following table lists the breast FNA biopsy codes differentiated by “with” or “without” imaging guidance and the type of guidance provided.

FINE NEEDLE ASPIRATION BIOPSY CPT
 FNA Bx w/o Imaging, first lesion   10021
 FNA Bx w/o Imaging, ea addt'l   10004
 FNA Bx w/ Ultrasound, first lesion   10005
 FNA Bx w/ Ultrasound, ea addt'l   10006
 FNA Bx w/Fluoro, first lesion   10007
 FNA Bx w/Fluoro, ea addt'l   10008
 FNA Bx w/CT, first lesion   10009
 FNA Bx w/CT, ea addt'l   10010
 FNA Bx w/MR   10011
 FNA Bx w/MR, ea addt'l   10012

Do not report 10004, 10021 in conjunction with 10005-10012 for the same lesion.

 

 The AMA’s CPT 2019 codebook guidelines, General Guidelines Fine Needle Aspiration (FNA) Biopsy, differentiate between FNA and needle core biopsies as follows:

A fine needle aspiration (FNA) biopsy is performed when material is aspirated with a fine needle and the cells are examined cytologically. A core needle biopsy is typically performed with a larger bore needle to obtain a core sample of tissue for histopathologic evaluation. FNA biopsy procedures are performed with or without imaging guidance.

 In addition, the CPT 2019 codebook lists the following important notes:

When more than one FNA biopsy is performed on separate lesions at the same session, same day, same imaging modality, use the appropriate imaging modality add-on code for the second and subsequent lesion(s).
When more than one FNA biopsy is performed on separate lesions, same session, same day, using different imaging modalities, report the corresponding primary code with modifier 59 for each additional imaging modality and corresponding add-on codes for subsequent lesions sampled.
This instruction applies regardless of whether the lesions are ipsilateral or contralateral to each other, and/or whether they are in the same or different organs/structures.
When FNA biopsy and core needle biopsy both are performed on the same lesion, same session, same day using the same type of imaging guidance, do not separately report the imaging guidance for the core needle biopsy. When FNA biopsy is performed on one lesion and core needle biopsy is performed on a separate lesion, same session, same day using the same type of imaging guidance, both the core needle biopsy and the imaging guidance for the core needle biopsy may be reported separately with modifier 59. When FNA biopsy is performed on one lesion and core needle biopsy is performed on a separate lesion, same session, same day using different types of imaging guidance, both the core needle biopsy and the imaging guidance for the core needle biopsy may be reported with modifier 59.

If a physical exam is performed in conjunction with a diagnostic mammogram or breast ultrasound and the results are discussed with the patient, is it appropriate to bill for an office visit (e.g., 99212) if performed in a private office setting?

It is only appropriate to bill for a consultation or other evaluation and management (E&M) service when the service is provided and documented according to established E&M guidelines. For breast interventional procedures, a brief review of history and physical exam and obtaining informed consent is not a separately reportable E&M service. The Relative (Value Unit) Update Committee (RUC) database clearly indicates that such discussion of findings with the patient is part of the valued work (and thus reporting this separately with an E&M code is unbundling).

A copy of the and E&M published guidelines are available on the Centers for Medicare and Medicaid Services web site. It is up to the provider to choose which published guidelines to follow. However, it is recommended that for auditing purposes a radiology practice use one set of guidelines, that is, either 1995 or 1997.

Is a consent form signed by the patient required for a breast cyst aspiration?

Yes, a signed informed consent form must be obtained prior to the performance of a breast cyst aspiration or breast core biopsy. Obtaining informed consent from the patient or appropriate designee as defined by local regulations for these breast procedures is no different from obtaining informed consent for any other invasive or interventional procedure.

Can you report a breast biopsy code multiple times when multiple samples are taken from the same lesion?

No, if multiple samples are taken from the same lesion, the biopsy code should be reported only once. However, when separate lesions are sampled during the same session, it is appropriate to report the biopsy codes multiple times based on the number of separate lesions sampled.

What is a breast tomosynthesis study, and how is it coded?

Breast tomosynthesis is a digital tomographic technique performed using multiple low-dose X-ray exposures. The resulting image data is reconstructed using standard computer algorithms to produce a series of sequential, stacked slices through the breast. This type of tomographic imaging enables the physician to view the breast(s) as thin, discrete image slices on a computer workstation. The addition of digital breast tomosynthesis (DBT) to conventional mammography has been shown to be more sen¬sitive and specific for breast cancer detection.

The Current Procedural Terminology (CPT®) Editorial Panel created three Cat¬egory I codes to describe unilat¬eral diagnostic (77061), bilateral diagnostic (77062), and screening (77063) breast tomosynthesis procedures, which became available for use as of January 1, 2015. However, CMS recognized 77063 only for screening DBT as an add-on code, but did not recognize the stand-alone diagnostic DBT codes 77061 and 77062. In place of using 77061 and 77062, CMS created the HCPCS Level II add-on code G0279 to describe diagnostic DBT, whether unilateral or bilateral.

My digital breast tomosynthesis (DBT) system has the ability to derive synthesized planar mammographic images from the tomosynthesis data set. If I am utilizing synthesized planar images rather than directly acquired full-field digital mammography (FFDM) images, how do I code for that?

黑料网 published in the Nov-Dec 2014 黑料网 Radiology Coding Source Q&A advice that a planar mammogram is a planar mammogram, regardless if that planar mammogram was directly acquired FFDM data or synthesized from the DBT data set. Planar mammograms are coded as 77065, 77066, 77067.

How should a diagnostic digital breast tomosynthesis (DBT) study performed without mammographic images be reported for a Medicare patient?

In 2018, the Centers for Medicare and Medicaid Services provided guidance to the 黑料网 stating that code G0279 (Diagnostic digital breast tomosynthesis, unilateral or bilateral (list separately in addition to 77065 or 77066) should be billed with 77065 or 77066, even if a diagnostic planar mammogram was NOT performed. Codes G0279 and 77065 should be reported to describe a unilateral diagnostic digital breast tomosynthesis (DBT), regardless if a planar unilateral diagnostic mammogram was performed. Codes G0279 and 77066 should be reported to describe a bilateral diagnostic DBT, regardless if a planar bilateral diagnostic mammogram was performed.

What supervision level is required for a diagnostic mammogram?

There is nothing in the regulations that requires supervision by a radiologist for mammography procedures. The October 31, 1997, the Healthcare Financing Administration [now known as the Centers for Medicare and Medicaid Services (CMS)] final rule clarifying the appropriate level of physician supervision for diagnostic tests payable under the Medicare Physician Fee Schedule does not apply to mammography procedures. Mammography is covered under the Food and Drug Administration’s Mammography Quality Standards Act (MQSA) guidelines, which also do not address the issue of supervision. However, the 黑料网 Practice Parameter of Screening and Diagnostic Mammography recommends direct supervision of diagnostic procedures. Direct supervision is defined as the physician being present and immediately available to furnish assistance and direction throughout the performance of the procedure. Direct supervision may also be accomplished via telemammography as long as the interpreting physician is immediately available.

What ICD-10 codes should be used to report a screening mammography study? Must this code be listed as the primary diagnosis code or would a positive finding be reported as the primary code?

Code Z12.31 (Encounter for screening mammogram for malignant neoplasm of breast) should be reported as the primary diagnosis code when screening mammography is performed even when the outcome of the study renders a positive finding.
As noted in f. A screening code may be a first-listed code if the reason for the visit is specifically the screening exam.

  • A screening code may be a first-listed code if the reason for the visit is specifically the screening exam.
  • Should a condition be discovered during the screening then the code for the condition may be assigned as an additional diagnosis. 

Also refer to - HCPCS and Diagnosis Codes for Mammography Services for additional information on the reporting of ICD-10 codes for mammography procedures.

Now that there are two breast ultrasound codes (Ultrasound, breast, unilateral, real time with image documentation, including axilla when performed; complete (76641), and limited (76642)), should referring physicians be asked to specify on the order whether they want limited or complete, or should the radiologist do what he/she thinks is appropriate no matter what is on the order?

The referring physician does not need to specify in an order if a complete or limited breast ultrasound is required. The type of ultrasound performed may be determined by the radiologist under the Ordering of Diagnostic Test Rule exemption, similar to the decision to perform a CT with or without contrast. For example, if the order is for breast ultrasound, the radiologist may determine if it should be a complete or limited ultrasound based on the medical necessity. However, if the referring physician specifies that a complete or limited ultrasound should be performed, the radiologist should speak with the referring physician if the radiologist disagrees with the type of study requested.

As noted above, the determination of whether a complete or limited study is performed falls under the Ordering of Diagnostic Tests Rule exemption, i.e., “Unless specified in the order, set the protocol for a given diagnostic, interventional, or therapeutic procedure ordered (e.g., number of radiographic views obtained, thickness of tomographic sections acquired, use or non-use of contrast media)” ).

For more information on the Ordering of Diagnostic Test Rule, reference Further Clarification on the Ordering of Diagnostic Tests Rule in the July- Aug 2003 黑料网 Radiology Coding Source

What makes up a limited and a complete breast ultrasound?

Per the CPT® 2019 codebook, Professional Edition, p. 494, code 76641 represents a complete ultrasound examination of the breast. Code 76641 consists of an ultrasound examination of all four quadrants of the breast and the retro-areolar region. It also includes ultrasound examination of the axilla, if performed.

Code 76642 consists of a focused ultrasound examination of the breast limited to the assessment of one or more, but not all, of the elements listed in code 76641. It also includes ultrasound examination of the axilla, if performed. If only the axilla is scanned, it should be coded as a limited extremity ultrasound, code 76882.

Use of ultrasound, without thorough evaluation of organ(s) or anatomic region, image documentation, and final written report, is not separately reportable.

If the same breast ultrasound study is performed on both breasts, how should that be coded?

The breast ultrasound codes are unilateral procedures. When the same type of breast ultrasound study is performed on both breasts, it is appropriate to report the code twice – once with an RT modifier and once with an LT modifier to designate a bilateral procedure was performed. For example, a complete breast ultrasound of both the right breast and left breast would be reported as 76641-RT and 76641-LT. Modifiers are payer specific; check with your third party payers to determine how you should report these procedures.

Does Medicare pay for a breast ultrasound when performed as a screening study?

No, Medicare does not pay for a breast ultrasound when performed as a screening study, as Medicare pays for screening studies only when they are mandated by Congress. Medicare will pay for a diagnostic breast ultrasound if medically indicated.

If breast ultrasound is performed as a screening study, a Medicare patient would be responsible for payment. Non-covered services (i.e., services excluded by law or under a non-benefit category) do not require that a waiver (Advance Beneficiary Notice) be signed, and the patient is responsible for payment. For more information view Medicare’s .

For most purposes, women whose breasts are classified as heterogeneously dense or extremely dense are considered to have dense breasts. Some states have enacted breast density notification laws that require women to be informed when a mammogram indicates that she has dense breasts. Other supplementary imaging tests may help find breast cancers that cannot be seen in dense breasts during a mammography exam, which include breast tomosynthesis, breast ultrasound, and breast MRI.1

 

Breast imagers are asked for second opinions quite often, which many times can reduce the amount of additional imaging and, more important, eliminate unnecessary biopsies. How would you report a second opinion or a re-read?

When a physician’s opinion or advice regarding a specific film is requested by another physician, and on examination of the film the consulting physician provides his or her opinion or advice to the requesting physician in a written report, the specific procedure code with a 26 modifier (professional component only) should be used. Some Medicare carriers require that modifier “77” also be used to indicate that a basic procedure or service performed by another physician had to be repeated. Please check with your local Medicare carrier for their guidelines. Other carriers and third-party payers may have different guidelines and may recommend the use of CPT code 76140 (Consultation on X-ray exam made elsewhere, written report).

As noted in the American Medical Association’s Principles of CPT Coding, if a patient comes to an office for a new or established patient visit and brings the physician his or her medical records, including X-rays, the review or reread of the X-rays would be considered part of the face-to-face evaluation and management service provided to the patient and would not be reported separately.
For more information on second opinions, please reference Dr. Richard Duszak’s article “Another Unpaid Second Opinion,” , Volume 2, Issue 9, Pages 793-794 (September 2005).

What national provider identifier (NPI) number should be reported when a self-referred mammography patient is seen?

The Centers for Medicare & Medicaid Services has instructed providers to use the institution’s NPI number for self-referred mammograms for all claims submitted on or after May 23, 2008. Please reference the CMS Change Request 6023 MLN Matters® Article which states:

  • Institutional providers submitting claims for self-referred mammography services will duplicate the institution’s own NPI in the attending physician NPI field on their claims; and
  • Suppliers submitting claims for self-referred mammography services will duplicate the supplier’s own NPI in the attending/referring physician NPI field on their claims.

We are currently performing planar bilateral breast scintigraphy studies using an FDA-approved optimized small field-of-view detector. How should this be reported?

Both the 黑料网 and the Society of Nuclear Medicine and Molecular Imaging recommend that CPT code 78800 (Radiopharmaceutical localization of tumor or distribution of radiopharmaceutical agent(s); limited area) be reported for a breast scintigraphy study of either one or both breasts. Although it is recognized that there is more work in imaging both breasts, the original intent of the multiple areas CPT code (78801) refers to multiple sites in the body versus both sides of the same part of the body. Just as imaging of the chest for other nuclear medicine procedures is considered one single limited area, both breasts are considered a single limited area as well.

Reference the 黑料网’s Breast Imaging Resources page for additional information.

Our state passed a law that requires mammography providers to directly inform their patients of their breast density category. The law includes an insurance mandate covering screening breast ultrasound for women with mammography-detected dense breasts.鈥 How should we code screening breast ultrasound exams?

The appropriate CPT code to report an ultrasound examination of the breast is 76641 (Ultrasound, breast, unilateral, real time with image documentation, including axilla when performed; complete) or 76642 (Ultrasound, breast, unilateral, real time with image documentation, including axilla when performed; limited).

Whenever a screening examination is performed, the screening ICD-10 [diagnosis] code is the first-listed, regardless of the findings or any procedure that may be performed as a result of the findings. Therefore, an ultrasound screening examination of the breast should be reported with ICD-10 code Z12.39 (Encounter for other screening for malignant neoplasm of breast). It is recommended that a secondary diagnosis be reported (e.g., R92.2, Inconclusive mammogram – dense breasts NOS) to communicate to the payer that the study was performed for a high risk patient.

As of October 1, 2018, ICD-10 code N63, Unspecified breast lump, now requires specification of the quadrant of the lump site. What is (are) the appropriate ICD-10 code(s) for a 3, 6, 9, and 12 o'clock breast lumps?

For Medicare patients, the Centers for Medicare & Medicaid Services gives direction on the coding of unspecified quadrants in the National Correct Coding Determination (NCD) for Mammograms, which states:

Contractors shall add ICD-10 diagnosis codes N63.10, N63.20 to covered diagnosis list effective October 1, 2018. Note: Dual diagnosis codes depicting specific quadrants can be reported instead of unspecified quadrants if found more appropriate by provider.

For more information click .

What CPT code should be used to report a core breast biopsy performed using both stereotactic and tomosynthesis imaging guidance?

The AMA/黑料网 Clinical Examples in Radiology Fall 2016 issue provides guidance on the reporting of both a stereotactic and tomosynthesis imaging-guided core breast biopsy as follows:

When a breast biopsy is performed using both stereotactic and tomosynthesis imaging guidance, it is appropriate to use CPT code 19081, Biopsy, breast, with placement of breast localization device(s) (eg, clip, metallic pellet), when per¬formed, and imaging of the biopsy specimen, when performed, percutaneous; first lesion, including stereotactic guidance.

If a combination stereotactic–tomosynthesis-guided biopsy is performed using a separate piece of equipment (such as a prone table) and the patient is moved to another unit for a post-procedure mammogram, it is appropriate to report the post-procedure mammogram separately. If the combination stereotactic–tomosyn¬thesis-guided biopsy is performed using a standard digital breast tomosynthesis mammography unit on which the post-procedure mammogram is also obtained, it is not appropriate to report the post-procedure mammogram separately.”